System Event Log Troubleshooting Guide for Intel
®
S5500/S3420 series Server Boards Memory subsystem
Revision 1.0 Intel order number G74211-001 61
Byte
Field
Description
13
Event Direction and
Event Type
[7] Event direction
0b = Assertion Event
1b = Deassertion Event
[6:0] Event Type = 6Fh (Sensor Specific)
14
Event Data 1
[7:6] 10b = OEM code in Event Data 2
[5:4] 10b = OEM code in Event Data 3
[3:0] Event Trigger Offset = 02h
15
Event Data 2
[7:5] Reserved. Set to 0.
[4] Channel Information Validity Check:
0b = Channel Number in Event Data 3 Bits[4:3] is not valid
1b = Channel Number in Event Data 3 Bits[4:3] is valid
[3] DIMM Information Validity Check:
0b = DIMM Slot ID in Event Data 3 Bits[2:0] is not valid
1b = DIMM Slot ID in Event Data 3 Bits[2:0] is valid
[2:0] Error Type:
000b = Parity Error Type not known
001b = Data Parity Error (not used)
010b = Address Parity Error
All other values reserved.