Kontron S5500 SEL Troubleshooting Manual de usuario Pagina 61

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 114
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 60
Memory subsystem System Event Log Troubleshooting Guide for Intel® S5500/S3420 series Server Boards
52 Intel order number G74211-001 Revision 1.0
9.1.2 Mirrored Redundancy State Sensor
This sensor provides the RAS Redundancy state for the Memory Mirrored Channel Mode.
Table 54: Mirrored Redundancy State Sensor Typical Characteristics
Byte
Field
Description
8
9
Generator ID
0001h = BIOS POST
11
Sensor Type
0ch = Memory
12
Sensor Number
01h
13
Event Direction and
Event Type
[7] Event direction
0b = Assertion Event
1b = Deassertion Event
[6:0] Event Type = 0Bh (Generic Discrete)
14
Event Data 1
[7:6] 10b = OEM code in Event Data 2
[5:4] 10b = OEM code in Event Data 3
[3:0] Event Trigger Offset as described in Table 55