Power Subsystems System Event Log Troubleshooting Guide for Intel® S5500/S3420 series Server Boards
24 Intel order number G74211-001 Revision 1.0
Byte
Field
Description
15
Event Data 2
Not used
16
Event Data 3
Not used
Table 16: Power Unit Status Sensor Sensor Specific Offsets Next Steps
Sensor Specific Offset
Description
Next Steps
Hex
Description
00h
Power down
System is powered down
Informational Event
04h
A/C Lost
AC removed
Informational Event
05h
Soft Power Control
Failure
Generally means power good was lost
in the system, causing a shutdown.
This could be cause by the power supply subsystem or system components
1. Verify all power cables and adapters are connected properly (AC cables as well as the cables
between PSU and system components).
2. Cross test PSU if possible.
3. Replace power subsystem.
06h
Power Unit Failure
Power subsystem experienced a
failure
Indicates a power supply failed.
1. Remove and reapply AC power.
2. If power supply still fails, replace it.
4.2.2 Power Unit Redundancy Sensor
This sensor is enabled on systems that support redundant power supplies. When a system has AC applied or if it loses redundancy of the
power supplies a message will get logged into the SEL.
Table 17: Power Unit Redundancy Sensors Typical Characteristics
Byte
Field
Description
11
Sensor Type
09h = Power Unit
12
Sensor Number
02h