System Event Log Troubleshooting Guide for Intel
®
S5500/S3420 series Server Boards Power Subsystems
Revision 1.0 Intel order number G74211-001 27
Typically means a fan inside the power supply is not cooling the
power supply. It may indicate the fan is failing.
Power supply configuration is not supported
Indicates that at least one of the supplies is not correct for your system
configuration.
1) Remove the power supply and verify compatibility.
2) If power supply is compatible it may be faulty. Replace it.
4.3.2 Power Supply AC Power Input Sensors
These sensors will log an event when a power supply in the system is exceeding its AC power in threshold.
Table 21: Power Supply AC Power Input Sensors Typical Characteristics
52h = Power Supply 1 AC Power Input
53h = Power Supply 2 AC Power Input
Event Direction and
Event Type
[7] Event direction
0b = Assertion Event
1b = Deassertion Event
[6:0] Event Type = 01h(Threshold)
[7:6] – 01b = Trigger reading in Event Data 2
[5:4] – 01b = Trigger threshold in Event Data 3
[3:0] – Event Trigger Offset as described in Table 22
Reading that triggered event
Threshold value that triggered event