System Event Log Troubleshooting Guide for Intel
®
S5500/S3420 series Server Boards
Processor subsystem
Revision 1.0 Intel order number G74211-001 43
Table 45: Processor Status Sensors – Next Steps
The processor exceeded the
maximum temperature.
This event normally only happens due to failures of the thermal solution:
1. Verify heatsink is properly attached and has thermal grease.
2. If system has a heatsink fan, ensure the fan is spinning.
3. Check all system fans are operating properly
4. Check that the air used to cool the system is within limits (typically 35°C)
Indicates processor is present
The processor exceeded the
maximum temperature.
Indicates processor is present