Kontron S5500 SEL Troubleshooting Manual de usuario Pagina 57

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 114
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 56
Processor subsystem System Event Log Troubleshooting Guide for Intel® S5500/S3420 series Server Boards
48 Intel order number G74211-001 Revision 1.0
8.4.3 QPI Fatal and Fatal #2
The system detected a QPI fatal or non-recoverable error. This is a fatal error.
Table 50: QPI Fatal Error Sensor Typical Characteristics
Byte
Field
Description
8
9
Generator ID
0033h = BIOS SMI Handler
11
Sensor Type
13h = Critical Interrupt
12
Sensor Number
17h
13
Event Direction and
Event Type
[7] Event direction
0b = Assertion Event
1b = Deassertion Event
[6:0] Event Type = 74h (OEM Discrete)
14
Event Data 1
[7:6] 10b = OEM code in Event Data 2
[5:4] 00b = Unspecified Event Data 3
[3:0] Event Trigger Offset = Reserved
15
Event Data 2
0-3 = CPU1-4
16
Event Data 3
Not used.
The QPI Fatal #2 Error is a continuation of QPI Fatal Error.
Table 51: QPI Fatal #2 Error Sensor Typical Characteristics
Byte
Field
Description
8
9
Generator ID
0033h = BIOS SMI Handler
11
Sensor Type
13h = Critical Interrupt
12
Sensor Number
18h