System Event Log Troubleshooting Guide for Intel
®
S5500/S3420 series Server Boards Power Subsystems
Revision 1.0 Intel order number G74211-001 29
Threshold value that triggered event
The following table describes the severity of each of the event triggers for both assertion and for deassertion.
Table 24: Power Supply Current Output % Sensor – Event Trigger Offset – Next Steps
Upper non critical
going high
PMBus* feature to monitor power
supply power consumption.
If you see this event, the system is using too much power on the output for
the PSU rating.
1. Verify the power budget is within the specified range.
2. Check http://www.intel.com/p/en_US/support/ for the power
budget tool for your system.
Upper critical
going high
4.3.4 Power Supply Temperature Sensors
The BMC will monitor one power supply temperature sensor for each installed PMBus* compliant power supply.
Table 25: Power Supply Temperature Sensors Typical Characteristics
56h = Power Supply 1 Temperature
57h = Power Supply 2 Temperature
Event Direction and
Event Type
[7] Event direction
0b = Assertion Event
1b = Deassertion Event
[6:0] Event Type = 01h (Threshold)