System Event Log Troubleshooting Guide for Intel
®
S5500/S3420 series Server Boards Power Subsystems
Revision 1.0 Intel order number G74211-001 25
Event Direction and
Event Type
[7] Event direction
0b = Assertion Event
1b = Deassertion Event
[6:0] Event Type = 0Bh (Generic Discrete)
[7:6] – 00b = Unspecified Event Data 2
[5:4] – 00b = Unspecified Event Data 3
[3:0] – Event Trigger Offset as described in Table 18
Table 18: Power Unit Redundancy Sensor – Event Trigger Offset – Next Steps
System is fully operational
System is not running in redundant
power supply mode
This event should be accompanied by specific power supply errors (AC
lost, PSU failure, and so on). Troubleshoot these events accordingly
non-redundant, sufficient from redundant
non-redundant, sufficient from insufficient
non-redundant, insufficient
non-redundant, degraded from fully redundant
redundant, degraded from non-redundant
4.3 Power Supply
The BMC monitors the power supply subsystem.