Vista de pagina 42
Cooling subsystem System Event Log Troubleshooting Guide for Intel® S5500/S3420 series Server Boards
34 Intel order number G74211-001 Revision 1.0
Table 31: Fan Redundancy Sensors Typical Characteristics
Byte
Field
Description
11
Sensor Type
04h = Fan
12
Sensor Number
46h
13
Event Direction and
Event Type
[7] Event direction
0b = Assertion Event
1b = Deassertion Event
[6:0] Event Type = 0Bh (Generic Discrete)
14
Event Data 1
[7:6] 00b = Unspecified Event Data 2
[5:4] 00b = Unspecified Event Data 3
[3:0] Event Trigger Offset as described in Table 32
15
Event Data 2
Not used
16
Event Data 3
Not used