Switching Commands AT8901/2/3
AT8901/2/3 CLI Reference Manual Page 2 - 68
Format no lldp transmit
Mode Interface Config
2.17.2 lldp receive
Use this command to enable the LLDP receive capability.
Default disabled
Format
lldp receive
Mode Interface Configuration
2.17.2.1 no lldp receive
Use this command to return the reception of LLDPDUs to the default value.
Format
lldp receive
Mode Interface Configuration
2.17.3 lldp timers
Use this command to set the timing parameters for local data transmission on ports
enabled for LLDP. The
<interval-seconds> determines the number of seconds to
wait between transmitting local data LLDPDUs. The range is 1-32768 seconds. The
<hold-value> is the multiplier on the transmit interval that sets the TTL in local data
LLDPDUs. The multiplier range is 2-10. The
<reinit-seconds> is the delay before
re-initialization, and the range is 1-0 seconds.
Default interval—30 seconds
hold—4
reinit—2 seconds
Format
lldp timers [interval <interval-seconds>] [hold <hold-
value>] [reinit <reinit-seconds>
]
Mode Global Config
2.17.3.1 no lldp timers
Use this command to return any or all timing parameters for local data transmission on
ports enabled for LLDP to the default values.
Format
no lldp timers [interval] [hold] [reinit]
Mode Global Config
2.17.4 lldp transmit-tlv
Use this command to specify which optional type length values (TLVs) in the 802.1AB
basic management set are transmitted in the LLDPDUs. Use
sys-name to transmit the
system name TLV. To configure the system name, see 6.6.1 “snmp-server” on page 6 -
16. Use
sys-descto transmit the system description TLV. Use sys-cap to transmit the
system capabilities TLV. Use
port-desc to transmit the port description TLV. To
configure the port description, see 2.1.4 “description” on page 2 - 3.
Default no optional TLVs are included