NSC2U Server—Server Component Installations and Upgrades
Kontron IP Network Server NSC2U
Product Guide, rev. 1.4 December 2009
28
3.2.6 Installing the Processor Air Duct
1. Place the processor air duct over the processor sockets and fan assembly, using
caution to make sure you do not pinch any cables beneath the edges of the air
duct.
2. Slide the air duct forward until it is flush with the front panel.
3. Ensure that the rear of the air duct is fastened to the metal tab on the chassis.
(“A”)
4. Replace the chassis cover if you have completed all work inside of the chassis.
3.3 Hot-Swappable Component Installation Procedures
The following components are hot-swappable and do not require powering down the
system or removing the chassis cover:
Hard disk drives
AC and DC power supplies
3.3.1 Installing or Replacing a Hard Drive
Up to six hot-swappable SAS drives can be installed in your NSC2U Server. You must
remove the front bezel to add or replace a hard drive in one of the six drive bays.
Caution: If you install fewer than six hard drives, the empty bays must have drive trays with
baffles in them to maintain proper system cooling.
Figure 11. Removing the Processor Air Duct
B
A
TS000544