Kontron Carrier Grade Server TIGH2UProduct Guide December 2009Rev. 1.2
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.213Introduction—TIGH2U Server1.4 Additional Information and SoftwareFor more te
TIGH2U Server—Server Component ReplacementsKontron Carrier Grade Server TIGH2UProduct Guide, rev.1.2 December 20091005.7 Replacing the Server BoardThe
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.2101Server Component Replacements—TIGH2U Server8. Open the bridge board connect
TIGH2U Server—Server Component ReplacementsKontron Carrier Grade Server TIGH2UProduct Guide, rev.1.2 December 200910210. Remove the six screws that at
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.2103Server Component Replacements—TIGH2U Server5.7.2 Installing the Server Boar
TIGH2U Server—Server Component ReplacementsKontron Carrier Grade Server TIGH2UProduct Guide, rev.1.2 December 20091046. Install the CPU fan assembly.
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.2105Server Component Replacements—TIGH2U Server7. Insert the tip of a small fla
TIGH2U Server—Server UtilitiesKontron Carrier Grade Server TIGH2U Product Guide, rev.1.2 December 20091066 Server Utilities6.1 Using the BIOS Setup Ut
Table 13. Keyboard CommandsKey Description<F1> Help - Pressing F1 on any menu invokes the general Help window. The left and right arrow key
TIGH2U Server—Server UtilitiesKontron Carrier Grade Server TIGH2U Product Guide, rev.1.2 December 20091086.2.1 Preparing for the UpgradeThe steps belo
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.2109Server Utilities—TIGH2U Server6.4 Clearing the PasswordIf the user or admin
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.211Features—TIGH2U Server2FeaturesThis chapter briefly describes the main featu
TIGH2U Server—TroubleshootingKontron Carrier Grade Server TIGH2UProduct Guide, rev.1.2, December 20091107 TroubleshootingThis chapter helps you ident
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.2111Troubleshooting—TIGH2U Server Are all standoffs in the proper location and
TIGH2U Server—TroubleshootingKontron Carrier Grade Server TIGH2UProduct Guide, rev.1.2, December 20091127.4 Specific Problems and Corrective ActionsT
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.2113Troubleshooting—TIGH2U Server Are the video monitor’s signal and power cab
TIGH2U Server—TroubleshootingKontron Carrier Grade Server TIGH2UProduct Guide, rev.1.2, December 2009114 Make sure your BIOS is current. Go tohttp:
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.2115Troubleshooting—TIGH2U Server7.4.13 Devices are not Recognized under Device
TIGH2U Server—TroubleshootingKontron Carrier Grade Server TIGH2UProduct Guide, rev.1.2, December 20091167.6 BIOS Error MessagesWhen a recoverable err
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.2117Troubleshooting—TIGH2U Server7.6.1 BIOS POST Beep CodesTable 16 lists the P
TIGH2U Server—WarrantyKontron Carrier Grade Server TIGH2UProduct Guide, rev.1.2 December 20091188 WarrantyThis Kontron product is warranted against de
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.2119Safety Information—TIGH2U ServerAppendix A: Safety InformationWarning: Alt
TIGH2U Server—FeaturesKontron Carrier Grade Server TIGH2UProduct Guide, rev.1.2 December 200912Availability Two hot-swappable 600 W power supplies in
TIGH2U Server—Safety InformationKontron Carrier Grade Server TIGH2UProduct Guide, rev.1.2 December 2009120Overcurrent protection: The server is design
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.2121Safety Information—TIGH2U ServerCaution: Ventilation -- The equipment rack
TIGH2U Server—Safety InformationKontron Carrier Grade Server TIGH2UProduct Guide, rev.1.2 December 2009122Wichtige SicherheitshinweiseLesen Sie zunäch
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.2123Safety Information—TIGH2U ServerSICHERHEISMASSNAHMEN: Immer wenn Sie die Ge
TIGH2U Server—Safety InformationKontron Carrier Grade Server TIGH2UProduct Guide, rev.1.2 December 2009124Consignes de sécuritéLisez attention toutes
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.2125Safety Information—TIGH2U ServerInstrucciones de seguridad importantesLea t
TIGH2U Server—Safety InformationKontron Carrier Grade Server TIGH2UProduct Guide, rev.1.2 December 2009126INSTRUCCIONES DE SEGURIDAD: Cuando extraiga
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.2127Safety Information—TIGH2U ServerInformazioni di Sicurezza importantiRivolge
TIGH2U Server—Safety InformationKontron Carrier Grade Server TIGH2UProduct Guide, rev.1.2 December 2009128 Se il sistema è stato a lungo in funzione,
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.2129Regulatory and Certification Information—TIGH2U ServerAppendix B: Regulato
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.213Features—TIGH2U Server2.1 Server ComponentsFigure 2 shows the TIGH2U Server
TIGH2U Server—Regulatory and Certification InformationKontron Carrier Grade Server TIGH2UProduct Guide, rev.1.2 December 2009130B.3 Electromagnetic Co
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.2131Regulatory and Certification Information—TIGH2U ServerThe CE marking on thi
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.211Getting Help—TIGH2U ServerAppendix C: Getting HelpC.1 World Wide WebTechnic
TIGH2U Server—FeaturesKontron Carrier Grade Server TIGH2UProduct Guide, rev.1.2 December 2009142.2 Back PanelFigure 3 shows the back panel of the TIGH
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.215Features—TIGH2U Server2.3 Front PanelFigure 4 shows the front panel of the T
TIGH2U Server—FeaturesKontron Carrier Grade Server TIGH2UProduct Guide, rev.1.2 December 200916Figure 5 shows the front panel of the TIGH2U Server wit
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.217Features—TIGH2U ServerFigure 6 shows the control panel. Figure 6. Control P
TIGH2U Server—FeaturesKontron Carrier Grade Server TIGH2UProduct Guide, rev.1.2 December 2009182.4 Rear Panel Ethernet PortsThe TIGH2U Server has two
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.219Features—TIGH2U Server2.6.1 TAM Board FeaturesThe TIGH2U Server TAM board ha
Kontron Carrier Grade Server TIGH2UProduct Guide, rev.1.2 December 20092Legal Lines and DisclaimersCopyright © 2009, Kontron AG. All Rights Reserved.A
Description DescriptionA BIOS Bank Select Jumper P CPU Power ConnectorB I/O Module Option Connector Q Main Power Connector C POST Code Diagnostic LE
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.221Features—TIGH2U Server2.9 Riser Card AssemblyThe Carrier Grade Server TIGH2U
TIGH2U Server—FeaturesKontron Carrier Grade Server TIGH2UProduct Guide, rev.1.2 December 2009222.10 Power SupplyThe power subsystem has a power distri
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.223Features—TIGH2U Server2.11.1 CPU 1 and Memory Cooling AreaOne of the system’
TIGH2U Server—FeaturesKontron Carrier Grade Server TIGH2UProduct Guide, rev.1.2 December 2009242.11.6 Cooling SummaryThe four-fan cooling subsystem of
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.225Server Component Installations and Upgrades—TIGH2U Server3 Server Component
TIGH2U Server—Server Component Installations and UpgradesKontron Carrier Grade Server TIGH2UProduct Guide, rev.1.2 December 200926Note: The front beze
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.227Server Component Installations and Upgrades—TIGH2U Server4. Remove the shipp
TIGH2U Server—Server Component Installations and UpgradesKontron Carrier Grade Server TIGH2UProduct Guide, rev.1.2 December 2009283.2.5 Removing the P
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.229Server Component Installations and Upgrades—TIGH2U Server3.2.6 Installing th
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.23Contents—TIGH2U ServerContents1Introduction...
TIGH2U Server—Server Component Installations and UpgradesKontron Carrier Grade Server TIGH2UProduct Guide, rev.1.2 December 2009303.3 Hot-Swappable Co
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.231Server Component Installations and Upgrades—TIGH2U Server3.3.1.2 Attaching a
TIGH2U Server—Server Component Installations and UpgradesKontron Carrier Grade Server TIGH2UProduct Guide, rev.1.2 December 2009323. With the drive tr
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.233Server Component Installations and Upgrades—TIGH2U Server3.3.2.1 Removing th
TIGH2U Server—Server Component Installations and UpgradesKontron Carrier Grade Server TIGH2UProduct Guide, rev.1.2 December 2009343.3.2.3 Installing o
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.235Server Component Installations and Upgrades—TIGH2U Server3.4.1.1 Configurati
TIGH2U Server—Server Component Installations and UpgradesKontron Carrier Grade Server TIGH2UProduct Guide, rev.1.2 December 2009363.4.1.2 BIOS Select
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.237Server Component Installations and Upgrades—TIGH2U Server3.4.1.3 DCD/DSR Sig
TIGH2U Server—Server Component Installations and UpgradesKontron Carrier Grade Server TIGH2UProduct Guide, rev.1.2 December 200938The total bandwidth
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.239Server Component Installations and Upgrades—TIGH2U Server3.4.2.1 Memory RASU
TIGH2U Server—ContentsKontron Carrier Grade Server TIGH2UProduct Guide, rev.1.2 December 200943.4 Internal System Component Configuration and Installa
TIGH2U Server—Server Component Installations and UpgradesKontron Carrier Grade Server TIGH2UProduct Guide, rev.1.2 December 2009403.4.2.3 DIMM Populat
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.241Server Component Installations and Upgrades—TIGH2U Server3.4.2.4 Non-Mirrore
TIGH2U Server—Server Component Installations and UpgradesKontron Carrier Grade Server TIGH2UProduct Guide, rev.1.2 December 2009423.4.2.5 Non-Mirrored
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.243Server Component Installations and Upgrades—TIGH2U Server3.4.2.7 DIMM Sparin
TIGH2U Server—Server Component Installations and UpgradesKontron Carrier Grade Server TIGH2UProduct Guide, rev.1.2 December 200944• DIMM D1 and DIMM D
Figure 26. Installing Memory DIMMsTS000278-revEACDBDIMM A1DIMM A2DIMM B1DIMM B2DIMM D2DIMM D1DIMM C2DIMM C1Branch 1Branch 0Kontron Carrier Grade Serve
TIGH2U Server—Server Component Installations and UpgradesKontron Carrier Grade Server TIGH2UProduct Guide, rev.1.2 December 2009465. Holding the DIMM
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.247Server Component Installations and Upgrades—TIGH2U Server3.4.5.2 Removing a
TIGH2U Server—Server Component Installations and UpgradesKontron Carrier Grade Server TIGH2UProduct Guide, rev.1.2 December 2009485. Pull the lever an
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.249Server Component Installations and Upgrades—TIGH2U ServerCaution: The unders
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.25Contents—TIGH2U Server5.2.2 Replacing the CPU Fans in the Bracket ...
TIGH2U Server—Server Component Installations and UpgradesKontron Carrier Grade Server TIGH2UProduct Guide, rev.1.2 December 2009505. Close the load pl
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.251Server Component Installations and Upgrades—TIGH2U Server3.5.2 Equipment Rac
TIGH2U Server—Optional Component InstallationsKontron Carrier Grade Server TIGH2UProduct Guide, rev.1.2 December 2009524 Optional Component Installati
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.253Optional Component Installations—TIGH2U Server4.1.3 Cable Routing ReferenceI
TIGH2U Server—Optional Component InstallationsKontron Carrier Grade Server TIGH2UProduct Guide, rev.1.2 December 200954Note: Only PCI-X/PCIe cards tes
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.255Optional Component Installations—TIGH2U ServerThe low-profile riser slot (J5
TIGH2U Server—Optional Component InstallationsKontron Carrier Grade Server TIGH2UProduct Guide, rev.1.2 December 2009564.2.2 Removing the PCI Riser Ca
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.257Optional Component Installations—TIGH2U Server9. Determine your next steps a
TIGH2U Server—Optional Component InstallationsKontron Carrier Grade Server TIGH2UProduct Guide, rev.1.2 December 2009584.2.4 Installing an Add-in Card
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.259Optional Component Installations—TIGH2U Server4.2.5 Installing the PCI Riser
TIGH2U Server—ContentsKontron Carrier Grade Server TIGH2UProduct Guide, rev.1.2 December 200967.4.10 System Boots When Installing a PCI Card ...
TIGH2U Server—Optional Component InstallationsKontron Carrier Grade Server TIGH2UProduct Guide, rev.1.2 December 2009606. If this is the last task you
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.261Optional Component Installations—TIGH2U Server4.4 Installing Remote Manageme
TIGH2U Server—Optional Component InstallationsKontron Carrier Grade Server TIGH2UProduct Guide, rev.1.2 December 2009624.4.2 Installing the Remote Man
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.263Optional Component Installations—TIGH2U Server2. Remove the processor air du
TIGH2U Server—Optional Component InstallationsKontron Carrier Grade Server TIGH2UProduct Guide, rev.1.2 December 2009644. Use the two screws provided
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.265Optional Component Installations—TIGH2U ServerNote: Your SMART Embedded USB
TIGH2U Server—Optional Component InstallationsKontron Carrier Grade Server TIGH2UProduct Guide, rev.1.2 December 200966•RAID DDR2 mini-DIMM•Intel® RAI
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.267Optional Component Installations—TIGH2U Server4.6.2 Installing the RAID Smar
TIGH2U Server—Optional Component InstallationsKontron Carrier Grade Server TIGH2UProduct Guide, rev.1.2 December 2009683. Lift the battery assembly fr
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.269Optional Component Installations—TIGH2U Server7. Remove the TAM board. For i
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.27Revision History—TIGH2U ServerRevision HistoryDate Revision DescriptionSeptem
TIGH2U Server—Optional Component InstallationsKontron Carrier Grade Server TIGH2UProduct Guide, rev.1.2 December 2009702. Remove the front panel bezel
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.271Optional Component Installations—TIGH2U Server4.7.2 Installing a New Optical
TIGH2U Server—Optional Component InstallationsKontron Carrier Grade Server TIGH2UProduct Guide, rev.1.2 December 2009724. If this is the last task you
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.273Server Component Replacements—TIGH2U Server5 Server Component Replacements5.
TIGH2U Server—Server Component ReplacementsKontron Carrier Grade Server TIGH2UProduct Guide, rev.1.2 December 2009745.2 Replacing the Fan AssembliesCa
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.275Server Component Replacements—TIGH2U Server5.2.1 Removing the CPU Fan Assemb
TIGH2U Server—Server Component ReplacementsKontron Carrier Grade Server TIGH2UProduct Guide, rev.1.2 December 2009765.2.2 Replacing the CPU Fans in th
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.277Server Component Replacements—TIGH2U Server3. Place the new fans into the fa
TIGH2U Server—Server Component ReplacementsKontron Carrier Grade Server TIGH2UProduct Guide, rev.1.2 December 2009785.2.4 Removing the PCI Fan Assembl
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.279Server Component Replacements—TIGH2U Server2. Disconnect the flex cable from
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.211Introduction—TIGH2U Server1 Introduction1.1 About this ManualThank you for p
TIGH2U Server—Server Component ReplacementsKontron Carrier Grade Server TIGH2UProduct Guide, rev.1.2 December 2009803. Disconnect the PCI fan assembly
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.281Server Component Replacements—TIGH2U Server5.2.5 Replacing the PCI Fans in t
TIGH2U Server—Server Component ReplacementsKontron Carrier Grade Server TIGH2UProduct Guide, rev.1.2 December 2009825.2.6 Installing the Fan Assembly1
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.283Server Component Replacements—TIGH2U Server5. Lay the flex cable over the PC
TIGH2U Server—Server Component ReplacementsKontron Carrier Grade Server TIGH2UProduct Guide, rev.1.2 December 2009845.3.1 Removing the TAM Board1. Rem
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.285Server Component Replacements—TIGH2U ServerNote: If you will be re-installin
TIGH2U Server—Server Component ReplacementsKontron Carrier Grade Server TIGH2UProduct Guide, rev.1.2 December 200986Note: If you are following these s
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.287Server Component Replacements—TIGH2U Server5.3.2 Removing the LED Light Pipe
TIGH2U Server—Server Component ReplacementsKontron Carrier Grade Server TIGH2UProduct Guide, rev.1.2 December 2009885.3.3 Installing the TAM BoardNote
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.289Server Component Replacements—TIGH2U Server2. Set the replacement TAM board
TIGH2U Server—IntroductionKontron Carrier Grade Server TIGH2UProduct Guide, rev.1.2 December 2009121.2 What Your Server IncludesYour Kontron Carrier G
TIGH2U Server—Server Component ReplacementsKontron Carrier Grade Server TIGH2UProduct Guide, rev.1.2 December 2009905. Remove the TAM board. For instr
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.291Server Component Replacements—TIGH2U Server13. Push the SFP board toward the
TIGH2U Server—Server Component ReplacementsKontron Carrier Grade Server TIGH2UProduct Guide, rev.1.2 December 2009925.4.2 Installing the Front Panel B
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.293Server Component Replacements—TIGH2U Server5.5 Replacing the Removable Drive
TIGH2U Server—Server Component ReplacementsKontron Carrier Grade Server TIGH2UProduct Guide, rev.1.2 December 2009945.5.2 Removing the SAS Backplane B
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.295Server Component Replacements—TIGH2U Server5.5.3 Installing a New SAS Backpl
TIGH2U Server—Server Component ReplacementsKontron Carrier Grade Server TIGH2UProduct Guide, rev.1.2 December 2009965.5.4 Installing the Drive Bay Ass
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.297Server Component Replacements—TIGH2U Server5.6 Replacing the Power Distribut
TIGH2U Server—Server Component ReplacementsKontron Carrier Grade Server TIGH2UProduct Guide, rev.1.2 December 2009989. Disconnect the five power cable
Kontron Carrier Grade Server TIGH2UDecember 2009 Product Guide, rev.1.299Server Component Replacements—TIGH2U Server5.6.2 Installing the Power Distri
Comentarios a estos manuales