Product Guide, rev. 1.4 December 2009
108
3. Remove the PCI fan assembly, including the flex cable that covers it. For
instructions, see Section 5.2.4, “Replacing the PCI Fans in the Fan Shroud” on
page 105.
4. Remove the CPU fan assembly. For instructions, see Section 5.2.1, “Removing the
CPU Fans” on page 100.
5. Disconnect all of the cables connected to the SFP board:
— SAS backplane power cable
— All four fan power cables
— Two power input cables from the power distribution board
—Flex cable
— RAID IBBU cable, if installed
— Front serial port cable
Use Section 33, “NSC2U Server System Cable Routing” on page 51 as a reference
for all of the connectors.
6. Remove the bridge board by opening the connector latch (Figure 94, “A”) and lifting
the board up from both ends. (“B”)
Figure 94. Removing the Bridge Board
TS000565