www.kontron.com
COMe-P2020 User Guide
50
Table 3-18: 0x00E: User Core1 Speed Register
ACTION D7 D6 D5 D4 D3 D2 D1 D0
READ NU NU NU NU NU NU NU cfg_core1_sp
eed
WRITENUNUNUNUNUNUNUcfg_core1_sp
eed
POWER UP11111111
BITFIELD DESCRIPTION
[D0] 00 Core 1 clock frequency is less than or equal to 1000 MHz.
01 Core 1 clock frequency is greater than 1000 MHz.
N O T I C E
Register value is no more used to force CPU strapping, but register is used for checksum calculation!
(write Register value to 0x00). Equivalent CPU strapping is hard coded in CPLD depends on board vari-
ant!
Table 3-19: 0x00F: User SerDes OLL Time-out Enable Register
ACTION D7 D6 D5 D4 D3 D2 D1 D0
READ NU NU NU NU NU NU NU cfg_srds_pll
_toe
WRITENUNUNUNUNUNUNUcfg_srds_pll
_toe
POWER UP11111111
BITFIELD DESCRIPTION
[D0] 00 Enable PLL lock time-out counter. The power-on-reset sequence
waits for the SerDes PLL to lock while the time-out counter has not
expired.
01 Disable PLL lock time-out counter. The power-on-reset sequence
waits indefinately for the SerDes PLL to lock.