Pagina 1 - Computer-on-Module (COM)

microETXexpress®-PV-XT Computer-on-Module (COM) Version 1.0

Pagina 2 - » Table of Contents «

Kontron microETXexpress-PV User’s Guide www.kontron.com 6 points, and the design of future-proof systems with a built-in upgrade path. The mod

Pagina 3

Kontron microETXexpress-PV User’s Guide www.kontron.com 96 PCI Plug&Play Settings Feature Option Description DMA Channel 0 DMA Channel 1

Pagina 4

Kontron microETXexpress-PV User’s Guide www.kontron.com 97 Feature Option Description 256M 512M 1024M 2048M CardBus devices 8.3.5 Boot Settin

Pagina 5 - 1 User Information

Kontron microETXexpress-PV User’s Guide www.kontron.com 98 Boot Settings Configuration Feature Option Description Quick Boot Disabled Enabl

Pagina 6 - 1.6 Technical Support

Kontron microETXexpress-PV User’s Guide www.kontron.com 99 Feature Option Description settings can be adjusting to fix the problem Hit ‘DEL’ M

Pagina 7 - 2 Introduction

Kontron microETXexpress-PV User’s Guide www.kontron.com 100 Boot Device Priority Feature Option Description 1st Boot Device Type: Boot devic

Pagina 8

Kontron microETXexpress-PV User’s Guide www.kontron.com 101 8.3.6 Hard Disk Drives Feature Option Description 1st Drive Specifies the boot

Pagina 9

Kontron microETXexpress-PV User’s Guide www.kontron.com 102 Removable Drives Feature Option Description 1st Drive Specifies the boot sequen

Pagina 10

Kontron microETXexpress-PV User’s Guide www.kontron.com 103 8.3.7 Security Settings Feature Option Description Supervisor Password Indicate

Pagina 11 - 3 Specifications

Kontron microETXexpress-PV User’s Guide www.kontron.com 104 8.3.8 Chipset Settings Feature Option Description North Bridge Configuration Sub

Pagina 12

Kontron microETXexpress-PV User’s Guide www.kontron.com 105 North Bridge Configuration Feature Option Description PCI MMIO Allocation: 4GB t

Pagina 13 - » S-States: S0, S3, S4, S5

Kontron microETXexpress-PV User’s Guide www.kontron.com 7 3 Specifications 3.1 Functional Specification Processor: Intel® Atom™ Technology »

Pagina 14 - Height on Top

Kontron microETXexpress-PV User’s Guide www.kontron.com 106 Video Function Configuration Feature Option Description DVMT Mode Select Fixed

Pagina 15 - Height on Bottom

Kontron microETXexpress-PV User’s Guide www.kontron.com 107 JILI Display Configuration Feature Option Description JDA Revision N/A Displays

Pagina 16

Kontron microETXexpress-PV User’s Guide www.kontron.com 108 Backlight Brightness Varies from 1 to 255 Boot values programmed in the Northbrid

Pagina 17

Kontron microETXexpress-PV User’s Guide www.kontron.com 109 option “GbE Controller” is set to “Enabled” GbE Wake up From S5 Enabled Disabled A

Pagina 18 - 3.6 MTBF

Kontron microETXexpress-PV User’s Guide www.kontron.com 110 Feature Option Description Enabled Disabled PCIe port on the south bridge Auto onl

Pagina 19 - 4 COM Connectors

Kontron microETXexpress-PV User’s Guide www.kontron.com 111 Feature Option Description IOxAPIC Enable Enabled PCIe port PCIE Port 5 IOxAPIC En

Pagina 20 - 4.1 Pin-Outs

Kontron microETXexpress-PV User’s Guide www.kontron.com 112 8.3.9 Exit Options Feature Description Save Changes and Exit Exit system setup,

Pagina 21

Kontron microETXexpress-PV User’s Guide www.kontron.com 113 » AH=Eah » AL=function number » DX=4648h (security word) » CL=board number (st

Pagina 22

Kontron microETXexpress-PV User’s Guide www.kontron.com 114 9 Appendix B: Architecture Information The following sources of information can h

Pagina 23

Kontron microETXexpress-PV User’s Guide www.kontron.com 115 » The Indispensable PC Hardware Book, Hans-Peter Messmer, Addison-Wesley, 1994, I

Pagina 24

Kontron microETXexpress-PV User’s Guide www.kontron.com 8 Display Interfaces » VGA: The maximum resolution supported is 2048 x 1536 @ 60Hz »

Pagina 25

Kontron microETXexpress-PV User’s Guide www.kontron.com 116 9.4 Programming » C Programmer’s Guide to Serial Communications, Second Edition

Pagina 26

Kontron microETXexpress-PV User’s Guide www.kontron.com 117 10 Appendix C: Document Revision History Revision Date Changes 0.1 20 Oct 11 Init

Pagina 27

Kontron microETXexpress-PV User’s Guide www.kontron.com 118 Corporate Offices Europe, Middle East and Africa Oskar-von-Mil

Pagina 28

Kontron microETXexpress-PV User’s Guide www.kontron.com 9 » HWM: Temperature monitoring for CPU and board temperature (external ON Semiconduc

Pagina 29

Kontron microETXexpress-PV User’s Guide www.kontron.com 10 3.3 Mechanical Specifications Module Dimensions » 95 mm x 95 mm ±0.2 mm (3.47 in

Pagina 30

Kontron microETXexpress-PV User’s Guide www.kontron.com 11 » Height varies depending on whether the optional cooling solution (either a pass

Pagina 31

Kontron microETXexpress-PV User’s Guide www.kontron.com 12 3.4 Electrical Specifications 3.4.1 Supply Voltage » +4.75V to +18V on the VCC_12

Pagina 32

Kontron microETXexpress-PV User’s Guide www.kontron.com 13 3.5 Environmental Specifications 3.5.1 Temperature 3.5.1.1 Commercial Temperature

Pagina 33

Kontron microETXexpress-PV User’s Guide www.kontron.com 14 Operating (without Kontron heat spreader plate assembly): » Maximum operating temp

Pagina 34

Kontron microETXexpress-PV User’s Guide www.kontron.com 15 4 COM Connectors The pin-outs for microETXexpress® interface connectors X1A (pri

Pagina 35

www.kontron.com » Table of Contents « 1 User Information ... 1 1.1 About This Document ...

Pagina 36

Kontron microETXexpress-PV User’s Guide www.kontron.com 16 Type Description DP-I/O Differential Pair Input/Output DP-I Differential Pair Input

Pagina 37

Kontron microETXexpress-PV User’s Guide www.kontron.com 17 Pin Signal Description Type Termination Comment A15 SUS_S3# Indicates Suspend to R

Pagina 38

Kontron microETXexpress-PV User’s Guide www.kontron.com 18 Pin Signal Description Type Termination Comment A39 USB4- USB Data- Port #4 DP-I/O

Pagina 39

Kontron microETXexpress-PV User’s Guide www.kontron.com 19 Pin Signal Description Type Termination Comment Data- A63 GPI1 General Purpose Inp

Pagina 40

Kontron microETXexpress-PV User’s Guide www.kontron.com 20 Pin Signal Description Type Termination Comment Clock 10K ohms A84 LVDS_I2C_DAT L

Pagina 41

Kontron microETXexpress-PV User’s Guide www.kontron.com 21 Pin Signal Description Type Termination Comment A110 GND (Fixed) Power Ground PWR

Pagina 42

Kontron microETXexpress-PV User’s Guide www.kontron.com 22 Pin Signal Description Type Termination Comment devices. B19 SATA1_RX+ SATA 1 Rece

Pagina 43

Kontron microETXexpress-PV User’s Guide www.kontron.com 23 Pin Signal Description Type Termination Comment B42 USB3- USB Data- Port #3 DP-I/O

Pagina 44

Kontron microETXexpress-PV User’s Guide www.kontron.com 24 Pin Signal Description Type Termination Comment B65 PCIE_RX1- PCIe 1 Receive Data-

Pagina 45

Kontron microETXexpress-PV User’s Guide www.kontron.com 25 Pin Signal Description Type Termination Comment B86 VCC_5V_SBY +5V Standby PWR - -

Pagina 46 - Table 13: Device Addresses

www.kontron.com 4.1.3 Connectors J2 and J3 – SODIMM DDR3 Memory Sockets ... 35 4.1.4 Connector J4 - XDP ...

Pagina 47

Kontron microETXexpress-PV User’s Guide www.kontron.com 26 Pin Signal Description Type Termination Comment input C6 IDE_D8 IDE Data Bus 8 I/O

Pagina 48 - Table 14: ATX Mode

Kontron microETXexpress-PV User’s Guide www.kontron.com 27 Pin Signal Description Type Termination Comment Data Bus line input C33 PCI_C/BE1#

Pagina 49

Kontron microETXexpress-PV User’s Guide www.kontron.com 28 Pin Signal Description Type Termination Comment Receive- (0) connected C54 TYPE0#

Pagina 50

Kontron microETXexpress-PV User’s Guide www.kontron.com 29 Pin Signal Description Type Termination Comment C78 PEG_RX8+ PCIe Graphics Receive

Pagina 51

Kontron microETXexpress-PV User’s Guide www.kontron.com 30 Pin Signal Description Type Termination Comment C102 PEG_RX15- PCIe Graphics Recei

Pagina 52 - 5 Special Features

Kontron microETXexpress-PV User’s Guide www.kontron.com 31 Pin Signal Description Type Termination Comment Channel 1 D17 IDE_CS3# IDE Chip Se

Pagina 53 - 5.3 Watchdog

Kontron microETXexpress-PV User’s Guide www.kontron.com 32 Pin Signal Description Type Termination Comment D40 PCI_AD22 PCI Address and Data

Pagina 54

Kontron microETXexpress-PV User’s Guide www.kontron.com 33 Pin Signal Description Type Termination Comment connected D64 RSVD Reserved Not co

Pagina 55 - 6 Design Considerations

Kontron microETXexpress-PV User’s Guide www.kontron.com 34 Pin Signal Description Type Termination Comment Transmit- (11) connected D90 GND (

Pagina 56 - 6.3 Onboard Fan Connector

Kontron microETXexpress-PV User’s Guide www.kontron.com 35 Figure 4: Onboard Connectors J1 - CPLD Debug 4.1.2 Connector J1 – Fan J1 is the 4

Pagina 57

www.kontron.com 7.2 Memory Area ... 57 7.3 I/O Address Map ...

Pagina 58 - 7 System Resources

Kontron microETXexpress-PV User’s Guide www.kontron.com 36 4.1.4 Connector J4 - XDP The eXtended Debug Port (XDP) connector is a 24-pin connec

Pagina 59 - Table 20: APIC Mode

Kontron microETXexpress-PV User’s Guide www.kontron.com 37 14 GND 4.1.7 PCI Express Interface The PCI Express* x1 lane is a fast connection i

Pagina 60

Kontron microETXexpress-PV User’s Guide www.kontron.com 38 COMexpress® Port ICH8M Port Description 2.0 (EHC2) USB7 USB9 Either USB 1.1 (UHCI5)

Pagina 61 - 7.3 I/O Address Map

Kontron microETXexpress-PV User’s Guide www.kontron.com 39 The SATA controller is part of the ICH8M. 4.1.10 Audio Interface The Intel® ICH8

Pagina 62

Kontron microETXexpress-PV User’s Guide www.kontron.com 40 LVDS Flat Panel Interface (JILI) The Intel® Atom processor has integrated 18-bit si

Pagina 63

Kontron microETXexpress-PV User’s Guide www.kontron.com 41 The LPC bus does not support DMA (Direct Memory Access) and therefore imposes limit

Pagina 64

Kontron microETXexpress-PV User’s Guide www.kontron.com 42 Table 12: LPC Addresses Address (HEX) Device 0000 - 00FF IBM PC compatible devices

Pagina 65 - Table 29: Hardware Monitor

Kontron microETXexpress-PV User’s Guide www.kontron.com 43 CFFFFFFF D0000000 - DFFFFFFF PCI VGA Controller / Audio Controller / USB Controller

Pagina 66 - 8 BIOS Operation

Kontron microETXexpress-PV User’s Guide www.kontron.com 44 stated in the COM.0 specification, rather than the edge triggered SYS_RESET# provid

Pagina 67

Kontron microETXexpress-PV User’s Guide www.kontron.com 45 To enable the single supply mode the BIOS setup must be changed. The “Battery Mode”

Pagina 68

Kontron microETXexpress-PV User’s Guide www.kontron.com 1 1 User Information 1.1 About This Document This document provides information abou

Pagina 69 - 8.3 BIOS Setup

Kontron microETXexpress-PV User’s Guide www.kontron.com 46 The implementation of this subsystem complies with the COM Express® specification.

Pagina 70 - 8.3.2 Module Info

Kontron microETXexpress-PV User’s Guide www.kontron.com 47 WARNING: The following signal is not 5V tolerant as required by the COM Express 2

Pagina 71 - Module Component Stepping

Kontron microETXexpress-PV User’s Guide www.kontron.com 48 5 Special Features 5.1 Hyper-Threading Hyper-threading (officially termed Hyper-

Pagina 72 - 8.3.3 Advanced Settings Menu

Kontron microETXexpress-PV User’s Guide www.kontron.com 49 5.3 Watchdog This feature is implemented through the LPC on the CPLD and offers a

Pagina 73 - CPU Settings Configuration

Kontron microETXexpress-PV User’s Guide www.kontron.com 50 0 GPI0 A54 1 GPI1 A63 2 GPI2 A67 3 GPI3 A85 4 GPO0 A93 5 GPO1 B54 6 GPO2 B57 7 GPO3

Pagina 74

Kontron microETXexpress-PV User’s Guide www.kontron.com 51 6 Design Considerations 6.1 Thermal Management 6.1.1 Commercial Grade Module (36

Pagina 75 - IDE Configuration

Kontron microETXexpress-PV User’s Guide www.kontron.com 52 6.3 Onboard Fan Connector This section describes how to connect an optional fan to

Pagina 76

Kontron microETXexpress-PV User’s Guide www.kontron.com 53 Connector J1 specifications and Kontron part numbers for the components are: » Pa

Pagina 77

Kontron microETXexpress-PV User’s Guide www.kontron.com 54 7 System Resources 7.1 Interrupt Request (IRQ) Lines Table 19: 8259 PIC Mode IRQ

Pagina 78 - Super I/O Configuration

Kontron microETXexpress-PV User’s Guide www.kontron.com 55 Table 20: APIC Mode IRQ # Used For Available Comment 0 Timer0 No - 1 Keyboard No -

Pagina 79 - ACPI Configuration

Kontron microETXexpress-PV User’s Guide www.kontron.com 2 1.5 Warranty This Kontron product is warranted against defects in material and work

Pagina 80

Kontron microETXexpress-PV User’s Guide www.kontron.com 56

Pagina 81

Kontron microETXexpress-PV User’s Guide www.kontron.com 57 7.2 Memory Area The first 640 KBytes of DRAM are used as main memory. With DOS, yo

Pagina 82

Kontron microETXexpress-PV User’s Guide www.kontron.com 58 I/O Address Used for Available Comment 0090 – 009F System Resources No Fixed 00A0 -

Pagina 83 - ASF Configuration

Kontron microETXexpress-PV User’s Guide www.kontron.com 59 Table 22: PCI Device IRQs PCI Device PCI IRQ Interface Comment Host Bridge / Memory

Pagina 84

Kontron microETXexpress-PV User’s Guide www.kontron.com 60 A0h JILI-EEPROM No EEPROM for JILI Data 4 7.5 System Management Bus (SMBus) Table

Pagina 85 - MARS Configuration

Kontron microETXexpress-PV User’s Guide www.kontron.com 61 Table 29: Hardware Monitor Sensor Function Temp 0 CPU Core 1 Temperature. TEMP 0 I

Pagina 86 - Battery 1 (if present)

Kontron microETXexpress-PV User’s Guide www.kontron.com 62 8 BIOS Operation 8.1 Determining the BIOS Version The microETXexpress®-PV-XT COM

Pagina 87 - Battery 2 (if present)

Kontron microETXexpress-PV User’s Guide www.kontron.com 63 Menu Bar The menu bar at the top of the window lists different menus. Use the ← arr

Pagina 88 - Watchdog Configuration

Kontron microETXexpress-PV User’s Guide www.kontron.com 64 Pressing <F1> on a menu brings up the General Help window that describes the

Pagina 89 - GPIO Configuration

Kontron microETXexpress-PV User’s Guide www.kontron.com 65 8.3 BIOS Setup NOTE: Default settings are in bold 8.3.1 Main Menu Feature Opt

Pagina 90 - MPS Configuration

Kontron microETXexpress-PV User’s Guide www.kontron.com 3 2 Introduction 2.1 The microETXexpress®-PV-XT COM The Kontron microETXexpress®-PV-

Pagina 91 - PCI Express Configuration

Kontron microETXexpress-PV User’s Guide www.kontron.com 66 System Overview Feature Option Description Module Info N/A Select sub-menu. 8.3.

Pagina 92 - WARNING: Settings other than

Kontron microETXexpress-PV User’s Guide www.kontron.com 67 Feature Option Description Module Info N/A Select sub-menu Board Name N/A Displays

Pagina 93 - Remote Access Configuration

Kontron microETXexpress-PV User’s Guide www.kontron.com 68 Revision (HW strap) 8.3.3 Advanced Settings Menu Feature Option Description CPU

Pagina 94 - Trusted Computing

Kontron microETXexpress-PV User’s Guide www.kontron.com 69 AHCI Configuration N/A Select sub-menu CPU Settings Configuration Feature Option

Pagina 95 - USB Configuration

Kontron microETXexpress-PV User’s Guide www.kontron.com 70 Feature Option Description Technology one additional logical CPU for each physical

Pagina 96

Kontron microETXexpress-PV User’s Guide www.kontron.com 71 IDE Configuration Feature Option Description ATA/IDE Configuration Disabled Compa

Pagina 97 - AHCI Configuration

Kontron microETXexpress-PV User’s Guide www.kontron.com 72 Feature Option Description the status of auto-detection of IDE devices Secondary I

Pagina 98 - 8.3.4 PCIPnP Settings

Kontron microETXexpress-PV User’s Guide www.kontron.com 73 Primary IDE Master Primary IDE Slave Feature Option Description Device Depends

Pagina 99

Kontron microETXexpress-PV User’s Guide www.kontron.com 74 Feature Option Description Vendor N/A Displays the vendor string of the disk. Size

Pagina 100 - PCI Plug&Play Settings

Kontron microETXexpress-PV User’s Guide www.kontron.com 75 Feature Option Description 3E8/IRQ4 2E8/IRQ3 Serial Port2 Mode SPP IrDA ASK IR Seri

Pagina 101 - 8.3.5 Boot Settings

Kontron microETXexpress-PV User’s Guide www.kontron.com 4 » ETXexpress® modules are Kontron COM Express® modules in the basic form factor (12

Pagina 102 - Boot Settings Configuration

Kontron microETXexpress-PV User’s Guide www.kontron.com 76 Feature Option Description General ACPI Configuration Submenu Allows configuration

Pagina 103

Kontron microETXexpress-PV User’s Guide www.kontron.com 77 Advanced ACPI Configuration Feature Option Description ACPI Version Features ACPI

Pagina 104 - Boot Device Priority

Kontron microETXexpress-PV User’s Guide www.kontron.com 78 OS must support the headless mode Chipset ACPI Configuration Feature Option Desc

Pagina 105 - 8.3.6 Hard Disk Drives

Kontron microETXexpress-PV User’s Guide www.kontron.com 79 ASF Configuration Feature Option Description ASF Support Enabled Disabled Enable

Pagina 106 - Removable Drives

Kontron microETXexpress-PV User’s Guide www.kontron.com 80 Hardware Health Configuration Feature Option Description PWM 1 Mode Setting Auto

Pagina 107 - 8.3.7 Security Settings

Kontron microETXexpress-PV User’s Guide www.kontron.com 81 Feature Option Description 075 Low Temperature 1 Limit Range = 0 – 127 Default = 06

Pagina 108 - 8.3.8 Chipset Settings

Kontron microETXexpress-PV User’s Guide www.kontron.com 82 Feature Option Description MARS Disabled Auto SMB Charger SMB Manager If carrier b

Pagina 109 - North Bridge Configuration

Kontron microETXexpress-PV User’s Guide www.kontron.com 83 Feature Option Description Device Name N/A Displays manufacturer’s name for the bat

Pagina 110

Kontron microETXexpress-PV User’s Guide www.kontron.com 84 Watchdog Configuration Feature Option Description CPLD Watchdog Timer Enabled Dis

Pagina 111

Kontron microETXexpress-PV User’s Guide www.kontron.com 85 GPIO Configuration Feature Option Description Enable GPIO Control Enabled Disab

Pagina 112 - South Bridge Configuration

Kontron microETXexpress-PV User’s Guide www.kontron.com 5 2.4 COM Express® Documentation This product manual serves as one of three principal

Pagina 113

Kontron microETXexpress-PV User’s Guide www.kontron.com 86 Feature Option Description GPI 3 Invert GPI Signal #B LOW High Allows selection of

Pagina 114

Kontron microETXexpress-PV User’s Guide www.kontron.com 87 PCI Express Configuration Feature Option Description Relaxed Ordering Auto Enable

Pagina 115

Kontron microETXexpress-PV User’s Guide www.kontron.com 88 Feature Option Description 256 bytes 512 bytes 1024 bytes 2048 bytes 4096 bytes fun

Pagina 116 - 8.3.9 Exit Options

Kontron microETXexpress-PV User’s Guide www.kontron.com 89 Remote Access Configuration Feature Option Description Remote Access Disabled En

Pagina 117 - 8.5 JIDA Information

Kontron microETXexpress-PV User’s Guide www.kontron.com 90 Feature Option Description Display Delay Delay 1 Sec Delay 2 Sec Delay 4 Sec during

Pagina 118 - 9.2 General PC Architecture

Kontron microETXexpress-PV User’s Guide www.kontron.com 91 USB Configuration Feature Option Description USB Devices Enabled: 2 Keyboards,

Pagina 119 - 9.3 Ports

Kontron microETXexpress-PV User’s Guide www.kontron.com 92 USB Mass Storage Device Configuration Feature Option Description USB Mass Storage

Pagina 120 - 9.4 Programming

Kontron microETXexpress-PV User’s Guide www.kontron.com 93 AHCI Configuration Feature Option Description ACHI Port0 N/A Selects sub-menu ACH

Pagina 121

Kontron microETXexpress-PV User’s Guide www.kontron.com 94 Feature Option Description Device N/A Shows device type. Vendor N/A Shows HDD name

Pagina 122

Kontron microETXexpress-PV User’s Guide www.kontron.com 95 Feature Option Description Plug & Play O/S No Yes No: the BIOS configures all t