Table 9. Error Beep Codes Provided by an Intel® Remote Management Module
Beep Code
Reason for the beeps and action to take
1 Control panel CMOS clear has been initiated.
1-5-1-1
Processor failure. Reseat or replace the failed
processor.
1-5-2-1
No processor is installed or the CPU 1 socket is
empty. Reseat or replace the failed processor.
1-5-2-3
Processor configuration error or CPU 1 socket is
empty. Reseat or replace the failed processor. In
a two-processor system, make sure the processors
are identical.
1-5-2-4
Front-side bus select configuration error.
1-5-4-2 DC power unexpectedly lost.
1-5-4-3
Chipset control failure.
1-5-4-4
Power control failure.