2: Flex Circuit /
SAS/SATA RAID
Baseboard
Front panel
3: LED/Switch Board
Front panel
LED/switch
4: 80mm Fan Power and
Front panel
Ganged cable to
5: 60mm Fan Power and
Front panel
Ganged cable to
7: TAM Front Panel TAM Module
Front Panel
8: USB SD Flash SD Flash Card
Front Panel
9: Alarms Cable TAM Module
Chassis Rear
4.2 Installing or Replacing Hard Disk Drives
Up to six hot-swappable SAS or SATA hard disk drives can be installed in your CG2100
server. The drives go into carriers that connect to the SAS/SATA backplane board once
the carriers with drives attached are inserted back into the drive bays. The CG2100
server ships with six drive carriers.
CAUTION: If you install fewer than six hard disk drives, the unused drive bays must
contain the empty carriers that ship with the server to maintain proper cooling.
The CG2100 server does not support all SAS/SATA hard disk drives. To see a list of
validated manufacturers and drive models, refer to the THOL. The latest version of
the THOL is located on the Kontron support website at http://us.kontron.com/support/.
(Search for CG2100, click on Product Downloads, then Compatibility Matrix).
You must remove the front bezel to add or replace a hard drive in one of the drive
bays. It is not necessary to remove the front chassis cover or to power down the
system. The hard drives are hot-swappable.
Removing an HDD Carrier from the Chassis
1. Remove the front bezel. For instructions, see “Removing the Front Cover“ in Section
3.2.
2. Select the drive bay where you want to install/replace the drive.
Drive bay 0 must be used first, then drive bay 1 and so on.
(Drive bay numbers are printed on the front panel below the drive bays.)
3. Remove the drive carrier by pressing the green button to open the lever. (Figure
26, “A”).
4. Pull the drive carrier out of the chassis.
Figure 26. Removing the Drive Carrier
Comentarios a estos manuales