Kontron MARS Smart Battery Kit Manual de usuario Pagina 32

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 35
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 31
MARS User´s Guide
In the following the most important information is shown, that can be read out of the SBS Manager
and the both batteries.
SBS Manager: SM-Bus address 14h (look also datasheet of LTC1760)
h Information of the system status
Which battery is present, is charged/discharged, sends a calibrate request
If AC is present
If power is good
A calibration is in process
Smart Batteries: SM-Bus address 16h (look also datasheet of the used Smart Battery)
Average Time to Empty
Remaining Capacity Alarm
Average Time to Full
Remaining Time Alarm
Charging Current
Temperature
Charging Voltage
Voltage
Battery Status (fully charged, over charged,
over temperature alarm)
Current
Relative State of Charge
Cycle count
Absolute State of Charge
Design Capacity
Remaining Capacity
Design Voltage
Full Charge Capacity
Run Time to Empty
h
It is possible to get only information of one battery at one time. After this the SM-Bus must be
connected to the other battery. This should be done by sending the hexadecimal word 1000h
Note:
(battery 1) or 2000h (battery 2) at command Code 01h to address 14h via the SM-Bus. (default:
battery 1)
Appendix B:
Interface to Operating Systems 31
Vista de pagina 31
1 2 ... 27 28 29 30 31 32 33 34 35

Comentarios a estos manuales

Sin comentarios