AT8402 Diagnostics running on the Carrier
Page 2 - 19 AT8402 CLI Reference Manual
Failure impact
• PPC-00060005 diagnostic code results from an I2C error. The impact is loss of
applications running on carrier host processor. This impacts at least Ethernet func
-
tionality and command line interface.
2.7.6 PPC_PCI
PCI bus test.
Test group: Diagnostics
Test case: ppc
Test procedureprocedure: PPC_PCI
Test host: Carrier
Test IC: quickturn
Test mode: normal
Diagnostic code: PPC-00060006
Description
This test checks the PCI devices present on the bus by reading the /proc/pci file.
# cat /proc/pci
PCI devices found:
Bus 0, device 1, function 0:
Class 0280: PCI device 14e4:b404 (rev 1).
IRQ 27.
Master Capable. Latency=128.
Non-prefetchable 32 bit memory at 0xbfff0000 [0xbfffffff].
#
Parameters: none
Result
• PCI seetings and configuration space of devices found are displayed (see above).
Failure impact
• PPC-00060006 diagnostic code results from an I2C error. The impact is loss of
applications running on carrier host processor. This impacts at least Ethernet func
-
tionality and command line interface.
2.7.7 PPC_FLASH_READ
Flash read test.
Test group: Diagnostics
Test case: ppc
Test procedure: PPC_FLASH_READ
Test host: Carrier
Test IC: quickturn
Test mode: normal
Diagnostic code: PPC-00060007