PB-TIM2 User’s Manual Chapter 4 Programming
• Mode 0 & Mode 1 : Defines the timer mode
Mode Value Function
0 0 Stops on 0 or (B) event
0 1 Ring Counter
1 0 Counts down, input (A) loads
counter
1 1 Counts up, input (A) used as a
strobe
• Reload : Defines timer mode 0 does not reload
1 reloads on 0
• Output : Defines output operation 0 passive if 0 in timer
1 toggles on timerr 0 detection
4.2.3 Channel Interrupt Pending Register
Read Only Register
Channel 0 1 2
Address $09 $29 $49
Bit 7 6 5
4 3 2 1 0
Function Trig Zero Gate Match
After Reset 0 0 0 0
Where • Match : A 1 in this location means an interrupt pending on MATCH
• Gate : A 1 in this location means an interrupt pending on GATE input (B)
• Zero : A 1 in this location means an interrupt pending on zero crossing
• Trig : A 1 in this location means an interrupt pending on TRIG input (A)