KTD-S0005-C Page 19 Parallel Port Interface
MOPSlcdLX User's Guide
10 Parallel Port Interface
The MOPSlcdLX incorporates a parallel port that can be set to uni-/bidirectional and supports EPP operating
modes.
10.1 Connector
The parallel port is available through the X15004 connector (26 pins). To have the signals available on a
standard parallel interface connector DSUB25 an adapter cable is required which is offered by KONTRON
(KAB-DSUB25-1, part number 96015-0000-00-0).
Header Pin Signal Name Function DSUB25
1 /STB Strobe 1
2 /AFD Autofeed 14
3 D0 Data 0 2
4 /ERR Error 15
5 D1 Data 1 3
6 /INIT Init 16
7 D2 Data 2 4
8 /SLIN Select in 17
9 D3 Data 3 5
10 GND Ground 18
11 D4 Data 4 6
12 GND Ground 19
13 D5 Data 5 7
14 GND Ground 20
15 D6 Data 6 8
16 GND Ground 21
17 D7 Data 7 9
18 GND Ground 22
19 /ACK Acknowledge 10
20 GND Ground 23
21 /BUSY Busy 11
22 GND Ground 24
23 PE Paper out 12
24 GND Ground 25
25 /SLCT Select out 13
26
VCC
1)
Power +5V ---
Note: 1) To protect the external power lines of peripheral device make sure that
- the wires have the right diameter to withstand the maximum available current.
- to enclosure of the peripheral device fulfills the fire-protecting conditions of IEC/EN 60950.