IPMI Firmware AM4022
Page 30 ID 1052-3624, Rev. 1.0
4.2 Sensor Thresholds
The AM4022 CPU module is available for two different operating temperature ranges. For each
operating temperature range, a set of temperature thresholds for the sensors is defined. The
standard temperature range uses thresholds defined by Table 11, and the extended tempera-
ture range uses thresholds defined by Table 12. Table 13 provides voltage sensor thresholds.
Table 11: Thresholds - Standard Temperature Range
Sensor Number /
ID String
0Eh /
A1:Temp
CPU
0Fh /
A1:Temp
PCH
11h /
A1:Temp
Air
Upper non-recoverable
115 °C 118 °C 100 °C
Upper critical
105 °C 108 °C 90 °C
Upper non-critical
95 °C 98 °C 80 °C
Normal max.
90 °C 93 °C 75 °C
Nominal
80 °C 83 °C 65 °C
Normal min.
3 °C 3 °C 0 °C
Lower non-critical
1 °C n.a. -5 °C
Lower critical
n.a. n.a. -7 °C
Lower non-recoverable
n.a. n.a. -10 °C
Table 12: Thresholds - Extended Temperature Range
Sensor Number /
ID string
0Eh /
A1:Temp
CPU
0Fh /
A1:Temp
PCH
11h /
A1:Temp
Air
Upper non-recoverable
115 °C 118 °C 100 °C
Upper critical
105 °C 108 °C 90 °C
Upper non-critical
95 °C 98 °C 80 °C
Normal max.
90 °C 93 °C 75 °C
Nominal
80 °C 83 °C 65 °C
Normal min.
3 °C 3 °C 0 °C
Lower non-critical
1 °C n.a. -40 °C
Lower critical
n.a. n.a. -42 °C
Lower non-recoverable
n.a. n.a. -45 °C