Kontron COMe-cOH2/COMe-cOH6 User’s Guide
www.kontron.com
37
NOTE: The termination resistors in this table are already mounted on the
microETXexpress® board. Refer to the PICMG COM Express® Design Guide
for information about additional termination resistors.
Figure 5: Onboard Connectors
J1 - CPLD Debug
4.1.2 Connector J1 – Fan
J1 is a connector for 3- or 4-wire fan control. By default, it is set for 4-
wire fan control. The 9W APU COMe-cOH# SKUs do not require a fan to function
fully in the 0°C to 60° temperature range. When active cooling is required,
the default population is the 4-wire fan option. See Section 6.3,Onboard
Fan Connectorfor more detailed information.
Table 7. J1 Fan Connector Pin-Out
Pin
Name
1
FAN_TACH
2
FAN_V_IN
3
FAN_GND
Vista de pagina 41