System Event Log Troubleshooting Guide for EPSD
Platforms Based on Intel
®
Xeon
®
Processor E5 4600/2600/2400/1600/1400 Product Families
Manageability Engine (ME) Events
Revision 1.1 Intel order number G90620-002 117
13.2 Node Manager Exception Event
A Node Manager Exception Event will be sent each time maintained policy power limit is exceeded over Correction Time Limit.
Table 94: Node Manager Exception Sensor Typical Characteristics
Byte
Field
Description
8
9
Generator ID
002Ch or 602Ch ME Firmware
11
Sensor Type
DCh = OEM
12
Sensor Number
18h
13
Event Direction and
Event Type
[7] Event direction
0b = Assertion Event
1b = Deassertion Event
[6:0] Event Type = 72h (OEM)
14
Event Data 1
[7:6] 10b = OEM code in Event Data 2
[5:4] 10b = OEM code in Event Data 3
[3] Node Manager Policy event
0 Reserved
1 Policy Correction Time Exceeded Policy did not meet the contract for the defined policy. The policy will continue to
limit the power or shut down the platform based on the defined policy action.
[2] Reserved
[1:0] 00b
15
Event Data 2
[4:7] Reserved
[0:3] Domain Id (Currently, supports only one domain, Domain 0)
16
Event Data 3
Policy Id
13.2.1 Node Manager Exception Event Next Steps
This is an informational event. Next steps depend on the policy that was set. See the Node Manager Specification for more details.