If it's embedded, it's Kontron. » Kontron User's Guide «AM4204Document Revision 1.4April 2010

Pagina 2 - Customer Service

ix AM4204www.kontron.comSafety RequirementsThe following safety precautions must be observed when installing or operating the AM4204. Kontron assumes

Pagina 3 - Table of Contents

x AM4204www.kontron.comPrefaceHow to Use This GuideThis user's guide is designed to be used as step-by-step instructions for installation, and as

Pagina 4

xi AM4204www.kontron.comAdvisory ConventionsSeven types of advisories are used throughout the user guides to provide helpful information or to alert y

Pagina 5

xii AM4204www.kontron.comUnpackingFollow these recommendations while unpacking:• Remove all items from the box. If any items listed on the purchase or

Pagina 6 - List of Figures

xiii AM4204www.kontron.comRegulatory Compliance StatementsFCC Compliance Statement for Class B DevicesThis equipment has been tested and found to comp

Pagina 7 - List of Tables

xiv AM4204www.kontron.comLimited WarrantyKontron grants the original purchaser of Kontron's products a TWO YEAR LIMITED HARDWARE WARRANTY as desc

Pagina 8 - Safety Instructions

1AM4204Chapter 1Product Descriptionwww.kontron.com1.1 Product Overview...21.2 What’s Included ...

Pagina 9

2 AM4204www.kontron.com1. Product Description1.1 Product OverviewThe AM4204 is an Advanced Mezzanine Card (AMC) from Kontron supporting both multi-cor

Pagina 10 - Safety Requirements

3 AM4204www.kontron.comDual Gigabit Ethernet Controller• Dual Gigabit Ethernet Controller Intel 82571EB• PCIe x4 interface to processor• 2 1000Base-BX

Pagina 11 - Customer Comments

4 AM4204www.kontron.com1.4 Hot Swap CapabilityThe AMC supports Full Hot Swap capability as required by AMC.0 R2.0. It can be removed from or installed

Pagina 12 - Advisory Conventions

i AM4204www.kontron.comRevision HistoryCustomer ServiceVisit our site at: www.kontron.com © 2010 Kontron, an International Corporation. All rights res

Pagina 13 - Unpacking

5 AM4204www.kontron.com1.5 Software SupportThe following table contains information related to software supported by the AM4204.Table 1-2: AM4204 Soft

Pagina 14 - CE Certification

6AM4204Chapter 2Board Featureswww.kontron.com2.1 Block Diagram ... 72.2 System Core ...

Pagina 15 - Limited Warranty

7 AM4204www.kontron.com2. Board Features2.1 Block DiagramFigure 2-1: Block DiagramCaviumCN5650600MHzTemp. SensorEdge ConnectorFRONT LEDs

Pagina 16 - Product Description

8 AM4204www.kontron.com2.2 System Core2.2.1 Cavium OCTEON Plus 5650• 12x MIPS64 R2 Cores; 600Mhz • Up to 14.4 Billion MIPS64 instructions per second•

Pagina 17 - 1. Product Description

9 AM4204www.kontron.com2.4 SFP Front IOThe four front SFP cage support multi-rate copper and fiber SFP modules. The ports are numbered on the front pa

Pagina 18 - 3 AM4204

10 AM4204www.kontron.com2.6 IPMIThe AM4204 supports an intelligent hardware management system based on the Intelligent Platform Management Interface (

Pagina 19 - 1.4 Hot Swap Capability

11 AM4204www.kontron.com* When XAUI is used, the Octeon Block for the connection will be PKO/IPD port 0, QLM1 GMX0 index 0.2.9 Front Panel LEDsFigure

Pagina 20 - 1.5 Software Support

12 AM4204www.kontron.com2.9.1 Hot Swap LED (Blue LED)The AM4204 board supports a blue Hot Swap LED mounted on the front panel. This LED indicates when

Pagina 21 - Board Features

13AM4204Chapter 3Chapter 3Installing the Boardwww.kontron.com3.1 Hot Swap Insertion Procedures... 143.2 Hot Swap Ext

Pagina 22 - 2. Board Features

14 AM4204www.kontron.com3. Installing the Board3.1 Hot Swap Insertion ProceduresThe AM4204 is designed for hot swap operation. Hot swapping allows th

Pagina 23 - 2.3 USB Flash Module

Table of Contentsii AM4204www.kontron.comTable of ContentsSafety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 24 - 2.4 SFP Front IO

15 AM4204www.kontron.comLED will be turned off. If the module FRU information is invalid or the carrier cannot provide the necessary payload power, th

Pagina 25 - 2.8 AMC Connector

16 AM4204www.kontron.com3.3 SoftwareThe AM4204 comes as a pre-installed system with all necessary OS, Filesystem, drivers and applications factory-ins

Pagina 26 - 2.9 Front Panel LEDs

17 AM4204www.kontron.comr - reset systemStarting shellGive root password for system maintenance(or type Control-D for normal startup):System Maintenan

Pagina 27 - 2.9.4 SFP LED

18 AM4204www.kontron.com• SFP module (optical or copper) for Ethernet connection to the Linux host• ipmitool v1.8.9 ( http://ipmitool.sourceforge.net/

Pagina 28 - Installing the Board

19 AM4204www.kontron.com : OEM : IP Address Source : Static AddressIP Address : 0.0.0.0Subnet Mask

Pagina 29 - 3. Installing the Board

20 AM4204www.kontron.com•-P <password>default: admin[root@router01 ipmitool-1.8.9]# ipmitool -I lanplus -H 10.0.1.145 -U admin -P admin mc infoD

Pagina 30 - 15 AM4204

21 AM4204www.kontron.com Board Extra : MAC=00:A0:A5:5D:23:9E/10 Product Manufacturer : Kontron Product Name : AM4204 Product Part

Pagina 31 - 3.4 System access

22 AM4204www.kontron.com~ #The connection is terminated by pressing the escape character sequence “~.” (without quotes).3.5 Using the cfgtoolA tool to

Pagina 32 - 3.4.3.1 Requirements

23 AM4204www.kontron.comDetailed description of these options:• -h | --helpThis option shows a list of possible settings.•-t | --statusThis option sho

Pagina 33 - /mnt/bin/ipmitool lan print 1

24 AM4204www.kontron.com• -n | --nofruThis option prevent FRU data update when changing an interface, pcie, or clock setting (obsolete)• -d | --debugT

Pagina 34 - 3.4.3.3 Configure SoL

Table of Contentsiii AM4204www.kontron.com3. Installing the Board. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 35

25AM4204Chapter 4Thermal Considerationswww.kontron.com4.1 Thermal Monitoring ... 264.2 External Therma

Pagina 36

26 AM4204www.kontron.com4. Thermal Considerations4.1 Thermal MonitoringTo ensure optimal operation and long-term reliability of the AM4204, all onboar

Pagina 37 - 3.5 Using the cfgtool

27 AM4204www.kontron.comTable 4-1:MMC Temperature Sensors ThresholdsTemperature values are measured with an accuracy of 1°C.4.2 External Thermal Regul

Pagina 38 - 23 AM4204

28 AM4204www.kontron.com4.2.2.1 How to read the diagramThe diagram contains one curve for 80% thermal load and one for 100%. Full thermal load is not

Pagina 39 - 24 AM4204

29 AM4204www.kontron.com4.2.3 Airflow ImpedanceIn order to determine the cooling requirements of the AM4204, the airflow impedance of the module has b

Pagina 40 - Thermal Considerations

30 AM4204www.kontron.comTable 4-2:Deviation of the Airflow Rate on the AM4204Inlet Velocity Deviation (%)CFM m/s LFM ZONE A ZONE B ZONE C ZONE D5 0.57

Pagina 41 - 4. Thermal Considerations

Chapter 5Chapter 5Software Setupwww.kontron.com5.1 MMC Firmware... 325.2 Bootloader...

Pagina 42 - 4.2.1 Forced Airflow

32 AM4204www.kontron.com5. Software SetupSoftware on the AM4204 includes the following parts:• Bootloader• OS (rootFS, kernel)• MMC FW5.1 MMC Firmware

Pagina 43 - 4.2.2.2 Airflow

33 AM4204www.kontron.com5.1.2 IPMI SensorsThe MMC includes many sensors for voltage or temperature monitoring and various others for pass/fail type si

Pagina 44 - 4.2.4 Airflow Paths

34 AM4204www.kontron.com5 B1:IPMBL State C3h (OEM Kontron)6Fh (Sensor Specific)For additional information, refer to section Kontron IPMB-L Link

Pagina 45 - 30 AM4204

Table of Contentsiv AM4204www.kontron.com5.3 Board Firmware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 46 - Software Setup

35 AM4204www.kontron.com12 B1:Temp Air Out 01h (Temperature)01h (Threshold Based)Temperature Sensor of the outlet regionSensor is only readable when

Pagina 47 - 5. Software Setup

36 AM4204www.kontron.com27 B1:Pres SFP-3 25h (Entity Present)6Fh (Sensor specific)The sensor shows presents or absents of SFP. No event is generate

Pagina 48 - 5.1.2 IPMI Sensors

37 AM4204www.kontron.com5.1.2.1 OEM sensor description5.1.2.1.1 Kontron FRU Info AgentTable 5-2:Kontron FRU info agent sensorEvent/Reading type codeSe

Pagina 49 - 34 AM4204

38 AM4204www.kontron.com5.1.2.1.2 Kontron IPMB-L Link5.1.2.1.3 Kontron MMC Firmware Upgrade StatusTable 5-3:Kontron IPMB-L Link sensorEvent/Reading ty

Pagina 50 - 35 AM4204

39 AM4204www.kontron.com5.1.2.1.4 Kontron Reset5.1.2.1.5 Kontron POST Code Value5.1.2.1.6 Kontron Diagnostic StatusTable 5-5:Kontron reset sensorEvent

Pagina 51 - 36 AM4204

40 AM4204www.kontron.com5.1.2.1.7 Kontron User SW upgradeStatus5.1.2.2 Sensor ThresholdsFollowing table shows sensor thresholds for voltagesTable 5-8:

Pagina 52 - Event trigger

41 AM4204www.kontron.com5.1.3 OEM commands5.1.3.1 OEM Get Firmware SysUpTime5.1.3.2 OEM Get Serial ConfigurationExample: Using onboardipmitool –l 3 ra

Pagina 53

42 AM4204www.kontron.com5.1.3.3 OEM Set Serial ConfigurationExample: Using onboardipmitool –l 3 raw 0x30 0x06 0xab 0xca 0xca 0xce 0xc9 <setting>

Pagina 54

43 AM4204www.kontron.comExample: Using onboard # ipmitool raw 0x3e 0x20 <ID> <STATE>Example: Using ipmitool on Kontron AMC carrier (e.g. A

Pagina 55

44 AM4204www.kontron.com5.1.3.5 OEM Get Control StateExample:ipmitool –l 0 raw 0x3e 0x21 0x005.1.4 Field Replaceable Unit (FRU) InformationThis FRU in

Pagina 56 - 5.1.3 OEM commands

List of Figuresv AM4204www.kontron.comList of FiguresFigure 2-1: Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 57 - 5.1.3.4 OEM Set Control State

45 AM4204www.kontron.com5.1.6 WatchdogThe complete startup and execution process is guarded using external watchdog timers implemented by the hardware

Pagina 58 - Example: Using onboard

46 AM4204www.kontron.com5.1.8.1 MMC Firmware Update using ipmitoolPrerequisites: a working TFTP server, DHCP server and network connectivity to the DH

Pagina 59 - 5.1.5 E-Keying

47 AM4204www.kontron.com5.1.9.1 MMC Firmware Update using IOL SessionTo setup an IOL session, please refer to chapter 3.4.3.2. The update will be done

Pagina 60 - 5.1.8 Updating MMC Firmware

48 AM4204www.kontron.comTable 5-10:Bootloader POST Code values5.2.2 Bootloader shell and optionsThe boot process can be interrupted by entering the bo

Pagina 61

49 AM4204www.kontron.comdataXa_flash_update ScriptCommand script to flash a binary image transferred with tftpboot to the active image flash partitio

Pagina 62 - 5.2 Bootloader

50 AM4204www.kontron.comThere are 3 different types of bootloader environment variables:• Script: The variable is a set of consecutive (more simple) b

Pagina 63 - 48 AM4204

51 AM4204www.kontron.com• Var: The variable controls a specific behavior of the bootloader startup sequence. E.g. the ‘bootdelay’ variable controls th

Pagina 64 - 49 AM4204

52 AM4204www.kontron.com5.2.3.1 Update from Bootloader CLIThe following procedure defines the update of the image 0 bootloader:• Start system and conn

Pagina 65 - 50 AM4204

53 AM4204www.kontron.com5.2.3.2 Update from WindRiver Linux ShellTo update the boardloader along with the Linux kernel BSP using the kex-flashimage to

Pagina 66 - 5.2.3 Bootloader Update

54 AM4204www.kontron.comWhen shipped from factory, image0 and image1 contain identical bootloader and firmware images and image0 system is booted by d

Pagina 67

List of Tablesvi AM4204www.kontron.comList of TablesTable 1-1 Board Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 68 - 5.3 Board Firmware

55 AM4204www.kontron.com5.3.1.2 Image swap using ipmitoolImage swap can also be achieved using the ipmitool from the Linux shell of the board. The fol

Pagina 69 - Size Linux parti

56 AM4204www.kontron.com5.3.3 Cavium Linux BSP5.3.3.1 Rebuilding the Cavium Linux BSPCavium Networks provides a SDK that includes Linux kernel and roo

Pagina 70 - 5.3.2 Updating Firmware

57 AM4204www.kontron.comIn case ‘quilt’ is not installed, use ‘patch’ instead:# for i in `cat patches/series`; do patch -p 1 < patches/$i; donePlea

Pagina 71 - 5.3.3 Cavium Linux BSP

58 AM4204www.kontron.comKCS: Reading boot image number : Image 0KCS: Reading interface settings: front x1 XAUI, p8..11 x4 GEKCS: Reading PCIe settings

Pagina 72

59 AM4204www.kontron.com5.3.3.3 Updating JFFS2 partitionThere are two Linux MTD partitions (mtd4 for image 0 and mtd9 for image 1) available that allo

Pagina 73

60 AM4204www.kontron.comAfter the build process has been finished, the (stripped) kernel image is stored in the export directory ‘kontron_t5516-vmlinu

Pagina 74 - 5.3.4 WindRiver Linux BSP

61 AM4204www.kontron.comThis will update flash image1 firmware, MMC firmware and FRU data in case that the old version is GA 2.04 or higher. Please re

Pagina 75

62 AM4204www.kontron.comThis will update flash image0 firmware to GA 2.05, but not MMC firmware and FRU data of the board. However, after rebooting to

Pagina 76

63 AM4204www.kontron.com• Copy the kernel built in step 1 into the tftpboot directory of the development host. E.g. the kernel for the WindRiver Linux

Pagina 77 - 5.3.6 Using the NFS Root FS

A-1 AM4204www.kontron.comA. Connectors PinoutsA.1 USB SSD Flash ModuleA.2 SFP Front IOSignal Pin Number Signal Pin NumberV_5V 1 NC 2USB DATA (-) 3 NC

Pagina 78

vii AM4204www.kontron.comSafety InstructionsBefore You BeginBefore handling the board, read the instructions and safety guidelines on the following pa

Pagina 79 - A. Connectors Pinouts

B-1 AM4204www.kontron.comB. Getting HelpIf, at any time, you encounter difficulties with your application or with any of our products, or if you simpl

Pagina 80 - B. Getting Help

B-2 AM4204www.kontron.comB.1 Returning Defective MerchandiseBefore returning any merchandise please do one of the following:• Call1 Call our Technical

Pagina 81 - B-2 AM4204

B-3 AM4204www.kontron.comB.2 When Returning a Unit• In the box, you must include the name and telephone number of a contact person, in case further ex

Pagina 82 - B.2 When Returning a Unit

C-1 AM4204www.kontron.comC. GlossaryAcronyms DescriptionsACL Access Control List. IP Access Control List.ACPI Advanced Configuration & Power Inter

Pagina 83 - C. Glossary

C-2 AM4204www.kontron.comCRC Cyclic Redundancy CheckCS1 Components Side 1 as describes in PICMG3.0.CS2 Components Side 2 as describes in PICMG3.0.CTCA

Pagina 84 - C-2 AM4204

C-3 AM4204www.kontron.comFRBxFault-Resilient Booting level [1-3]. A term used to describe system features and algorithms that improve the likelihood o

Pagina 85 - C-3 AM4204

C-4 AM4204www.kontron.comIPM Intelligent Platform ManagementIPMB Intelligent Platform Management BusIPMB-0 Intelligent Platform Management Bus Channel

Pagina 86 - C-4 AM4204

C-5 AM4204www.kontron.comMP MultiProcessorMPS MultiProcessor SpecificationMRCMemory Reference Code. Chipset specific code provided by the manufacturer

Pagina 87 - C-5 AM4204

C-6 AM4204www.kontron.comRHEL Red Hat Enterprise LinuxRMS Root Mean SquareRoHS Restriction of the Use of Certain Hazardous SubstancesROMRead Only Memo

Pagina 88 - C-6 AM4204

C-7 AM4204www.kontron.comSSHSecure SHell. A network protocol that allows data to be exchanged over a secure channel between two computers.TCLKA Teleco

Pagina 89 - C-7 AM4204

viii AM4204www.kontron.comPreventing Electrostatic DischargeStatic electricity can harm system boards. Perform service at an ESD workstation and follo